Sector
Commercial
End-use
Lighting
Project Number
ET12PGE1271
To better understand the potential for energy savings through the implementation of bi-level lighting controls in exterior parking and pedestrian spaces, motion detection and data acquisition technologies were installed in selected areas at a total of eight sites in SCE, BPA, and PG&E...
Sector
Residential
End-use
Whole Building, Other, HVAC, Lighting
Project Number
ET13PGE1011
This report presents the results of detailed monitoring of the Cottle Zero Net Energy (ZNE) Home over 12 months from April 1st, 2013 through March 31st, 2014. The home has been occupied during the monitoring period by a family of five who moved in February 2013. Analysis includes evaluation of ZNE...
Sector
Residential
End-use
Whole Building, Lighting, Other, Process, Water Heating/DHW/HPWH, HVAC
Project Number
ET12PGE2471
The Honda Smart Home is a fully functional zero net energy (ZNE) home located in Davis, California, containing many advanced design elements. Pacific Gas and Electric Company (PG&E) partnered with Honda to monitor the performance and grid integration of the Honda Smart Home. PG&E also...
Sector
Residential
End-use
Whole Building
Project Number
ET11PGE3074
This Emerging Technologies report documents the results of the Opower/Honeywell Smart Thermostat field assessment. The assessment was launched with two waves of recruitment in mid-to-late 2012. Under a recruit-and-deny research design, a retail intercept recruitment campaign resulted in 695...
Sector
Commercial, Public
End-use
Water Heating/DHW/HPWH
Project Number
ET08SCG0005
Project Summary Field test showed ozone injection system in a jail reduces 88.1% of gas and 18.8% of total water usage, plus unspecified detergent and...
Sector
Commercial, Public, Residential
End-use
HVAC
Project Number
E12SCG0018
Project Summary Replacing existing and vintage gravity wall furnaces with high-efficiency models can save gas in apartments, average 35.5...
Sector
Commercial
End-use
Water Heating/DHW/HPWH
Project Number
E12SCG0019
Project Summary
Field tests confirmed 1.07 gpm appeared to be the low limit for pre-rinse spray valves used in 6 restaurants in the LA area. The low-flow retrofit achieved an average of 24.9% energy savings, despite an observed increase in average daily use time. The energy and water savings...
Sector
Commercial, Public, Residential
End-use
Water Heating/DHW/HPWH
Project Number
ET12SCG0003
Project Summary
Retrofit by adding VFD controller to fractional horsepower Hot Water Recirculator in single loop domestic use for apartments and hotels, etc. can save gas 15.6% with a compensating but modest increase in hot water usage of 13.4%; or an average gas savings of about 27 therms per...
Sector
Commercial
End-use
Whole Building, Lighting, HVAC, Water Heating/DHW/HPWH
Project Number
ET13SDG1021
HGW Architects is the first commercial ZNE building in San Diego. SDG&E ET collaborated with Savings by Design to make this happen. ET then conducted a comprehensive study to understand modeled vs. actual building performance. The analysis discusses data discrepancies and methods used to...
Sector
Commercial, Agricultural, Industrial, Other
End-use
Process
Project Number
ET13PGE1081
Lab testing was conducted to evaluate the efficiency at various loads for PMAC motors at the 3 and 5 HP sizes compared with Premium Efficiency Induction Motor (PEIM) technology. Lab testing found efficiency increases to be between 2% and 24% for the 3 HP motor and 4% to 24% for the 5 HP motor,...